How to drain a wall-mounted boiler with high water pressure?
Wall-hung boilers are one of the common heating equipment in modern homes, but excessive water pressure is a common problem during use. Excessive water pressure may cause equipment to operate abnormally or even be damaged. This article will introduce in detail the reasons for high water pressure in wall-mounted boilers, drainage methods and precautions to help you solve the problem quickly.
1. Reasons for high water pressure in wall-hung boilers

Excessive water pressure in wall-mounted boilers is usually caused by the following reasons:
| Reason | Description |
|---|---|
| Too much water | The user's improper operation when replenishing water causes the water pressure to exceed the normal range (usually 1-2 bar). |
| temperature rise | When a wall-mounted boiler is heated, the water expands due to heat, causing the pressure to rise. |
| System failure | The safety valve or expansion tank is faulty and the pressure cannot be adjusted properly. |
2. How to judge whether the water pressure is too high
Wall-hung boilers are usually equipped with a pressure gauge, and the normal water pressure range is 1-2bar. If the pressure exceeds 2.5bar, the water pressure is too high and needs to be dealt with in time.
| Pressure value (bar) | Status | Handling suggestions |
|---|---|---|
| 1.0-2.0 | normal | No action required |
| 2.0-2.5 | On the high side | Watch to see if it continues to rise |
| ≥2.5 | too high | Immediately drain water and reduce pressure |
3. Drainage method for wall-mounted boilers with high water pressure
The following are the specific steps for drainage and pressure reduction:
Step 1: Turn off the power to the wall-hung boiler
To ensure safety, the power of the wall-hung boiler must be turned off before draining water to avoid operating the equipment while it is running.
Step 2: Find the drain valve
The drain valve is usually located at the bottom of the wall-mounted boiler or at a low level in the heating system. Please refer to the instruction manual for the specific location.
Step 3: Connect the drain pipe
Connect the drain pipe to the outlet of the drain valve, and put the other end into a bucket or floor drain to avoid water splashing.
Step 4: Slowly open the drain valve
Rotate the drain valve counterclockwise to slowly drain the water while observing the pressure gauge until the pressure drops to about 1.5bar.
Step 5: Close the drain valve and check
After drainage is completed, close the drain valve, check if there is any water leakage, and then restart the wall-hung boiler.
4. Precautions
1. When draining, avoid water flowing too fast to avoid sudden pressure drops affecting the equipment.
2. If the pressure continues to rise after draining, the expansion tank may be faulty, and it is recommended to contact a professional for repair.
3. Check the pressure of the wall-hung boiler regularly to avoid long-term high-pressure operation.
5. Frequently Asked Questions
| question | Answer |
|---|---|
| What should I do if the drain valve cannot be opened? | The valve may be corroded. Do not force the operation. It is recommended to contact after-sales service. |
| The pressure still does not drop after draining? | There may be other faults in the system, such as a failure of the safety valve, which requires professional maintenance. |
| How often should the water pressure of a wall-hung boiler be checked? | It is recommended to check once a month, especially before and after the heating season. |
Summary
Excessive water pressure in wall-mounted boilers is a common problem that needs to be dealt with promptly. Through correct drainage operation, the pressure can be effectively reduced and the normal operation of the equipment can be ensured. If you encounter a problem that cannot be solved, be sure to contact a professional for maintenance to avoid greater losses caused by improper operation.